Commit Graph
96 Commits
Author SHA1 Message Date
epenetandGitHub 7169d52010 Remove import annotations from core (#169547) 2026-04-30 20:34:43 +02:00
LamarqeandGitHub 566ff6d1d5 Add frequency unit conversion (#167537) 2026-04-09 17:16:02 +02:00
481eb66bc5 Add unit 'µA' for the units of electric current (#166786)
Co-authored-by: Ariel Ebersberger <[email protected]>
2026-04-07 14:48:21 +02:00
Pierre SassoulasandGitHub 36d6b4dafe Use clearer number notation for very small and very large literals (#164521) 2026-03-02 14:06:19 +01:00
Ludovic BOUÉandGitHub 3ee20d5e5c Add ppm to NITROGEN_DIOXIDE units (#162983) 2026-02-16 13:32:39 +01:00
Ludovic BOUÉandGitHub 3d354da104 Added ppm support for the ozone device class in sensor (#162996) 2026-02-14 19:57:16 +01:00
epenetandGitHub bf6643643b Reformat lambda (core) (#162382) 2026-02-06 12:24:48 +01:00
Gage BenneandGitHub d481c1bcc5 Improve accuracy of blood glucose conversion factor (#161644) 2026-02-02 12:19:16 +01:00
Thomas55555andGitHub 78212245dd Add ppb as a valid UOM for sensor/number NO device class (#161379) 2026-01-22 11:34:29 +01:00
epenetandGitHub 4f52b0363d Reorder unit conversion classes alphabetically (#161364) 2026-01-21 15:53:43 +00:00
b40046264d Add ppb as a valid UOM for sensor/number Ozone device class (#159328)
Co-authored-by: epenet <[email protected]>
2026-01-21 08:32:23 +01:00
27117c9d17 Add ppb as a valid UOM for sensor/number NO2 device class (#159426)
Co-authored-by: Abílio Costa <[email protected]>
2026-01-20 22:35:11 +00:00
Thomas55555andGitHub bc28c8fd3c Add ppb as a valid uom for sensor/number CO device class (#159554) 2026-01-20 16:07:24 +01:00
Thomas55555andGitHub 48852bab7a Add ppb as a valid UOM for sensor/number SO2 device class (#159431) 2026-01-19 23:32:45 +00:00
Rene NulschandGitHub 19f8d9d41b Fix ZeroDivisionError for inverse unit conversions (#159161) 2025-12-23 21:25:19 +01:00
StaleLoafOfBreadandGitHub f1ee0e4ac9 Add support for gallons per day as a unit of volume flow rate (#157394) 2025-11-27 20:42:16 +01:00
d7f9a7114d Deprecate TemperatureConverter.convert_interval (#155689)
Co-authored-by: Copilot <[email protected]>
Co-authored-by: Erik Montnemery <[email protected]>
Co-authored-by: epenet <[email protected]>
2025-11-04 13:40:41 +01:00
krahabbandGitHub afeaf2409f Add TEMPERATURE_DELTA device class to Number and Sensor entities (#147358) 2025-10-15 11:49:12 +02:00
3e20c506f4 Add gallons per hour as volume flow rate unit (#154246)
Co-authored-by: Christopher Fenner <[email protected]>
2025-10-14 16:16:48 +02:00
DomochipandGitHub 8464dad8e0 Add milliPascal (mPa) as unit of measurement for Pressure (#153087) 2025-10-14 12:38:14 +01:00
wittypluckandGitHub e4ea79866d Add support for μg/m³ for Carbon Monoxide (#153158) 2025-10-13 10:08:55 +02:00
epenetandGitHub b25622f40e Use SI constants in CO unit converter (#153187) 2025-10-10 14:59:20 +02:00
ee67619cb1 Add mg/m³ as a valid UOM for sensor/number Carbon Monoxide device class (#154074)
Co-authored-by: Copilot <[email protected]>
Co-authored-by: Abílio Costa <[email protected]>
2025-10-10 11:31:31 +01:00
Erik MontnemeryandGitHub 5975cd6e09 Revert "Add mg/m³ as a valid UOM for sensor/number Carbon Monoxide device class" (#153196) 2025-09-29 15:43:13 +01:00
Erik MontnemeryandGitHub f0c29c7699 Revert "Add comment on conversion factor for Carbon monoxide on dependency molecular weight" (#153195) 2025-09-29 14:56:42 +02:00
Abílio CostaandGitHub b26b1df143 Fix unitless converter missing valid units (#152665) 2025-09-22 15:19:31 +01:00
Jan BouwhuisandGitHub 472d70b6c9 Add comment on conversion factor for Carbon monoxide on dependency molecular weight (#152535) 2025-09-18 15:36:12 +02:00
Jan BouwhuisandGitHub 5eef6edded Add mg/m³ as a valid UOM for sensor/number Carbon Monoxide device class (#152456) 2025-09-17 22:04:23 +01:00
Alessandro ManighettiandGitHub eb4a873c43 Add m/min of speed sensors (#146441) 2025-09-16 18:02:22 +02:00
Bram GerritsenandGitHub a3a4433d62 Add missing unit conversion for BTU/h (#152300) 2025-09-14 19:00:44 +02:00
4c22264b13 Add support for inH₂O pressure unit (#148289)
Co-authored-by: Erik Montnemery <[email protected]>
2025-09-12 11:24:45 +02:00
Mike KellyandGitHub 1cca65b5c5 Add MCF (1000 Cubic Feet) as an alternate unit of measure for volume (#150015) 2025-09-04 09:29:37 +03:00
stephan-carstensandGitHub fc4b5f66ff Extend UnitOfApparentPower with 'kVA' (#151420) 2025-08-31 00:05:07 +01:00
Christian FetzerandGitHub 0dc2a5a02c Add m³/min as volume flow rate unit (#151051) 2025-08-24 20:30:25 +01:00
Ludovic BOUÉandGitHub cc4b9e0eca Extend UnitOfReactivePower with 'mvar' (#150415) 2025-08-14 11:46:06 +02:00
eb4b75a9a7 Extend UnitOfApparentPower with 'mVA' (#150422)
Co-authored-by: Martin Hjelmare <[email protected]>
2025-08-13 15:56:04 +02:00
MichaelandGitHub 50047f0a4e Add new device class for absolute humidity (#148567) 2025-07-14 11:46:17 +02:00
Franck NijhofandGitHub bca4793c69 Add concentration conversion support for mg/m³ (#145325) 2025-05-23 14:24:18 +01:00
Franck NijhofandGitHub fb0cb7cad6 Add Wh/km unit for energy distance (#145243) 2025-05-20 12:16:27 +01:00
alorenteandGitHub 3a58d97496 Fix wrong UNIT_CLASS for reactive energy converter (#144982) 2025-05-15 18:27:16 +01:00
alorenteandGitHub 1d47dc41c9 Add reactive energy device class and units (#143941) 2025-05-15 12:05:46 +01:00
Abílio CostaandGitHub 6b35b069b2 Remove duplicated code in unit conversion util (#144912) 2025-05-14 22:05:29 +01:00
MichaelandGitHub 3405b2549b Add new units L/h , L/s and m³/s to volume flow rate sensor device class (#143625)
add new units L/h , L/s and m³/s
2025-04-25 00:17:47 +02:00
J. Nick KostonandGitHub e2c050ed40 Cache sensor precision calculation (#140019) 2025-03-07 16:14:22 -10:00
84ae476b67 Energy distance units (#136933)
Co-authored-by: Abílio Costa <[email protected]>
2025-01-31 14:22:25 +00:00
Lukas SchlöttererandGitHub 7b63c17101 Add kV and MV unit conversion for voltages (#135396) 2025-01-13 13:00:35 +01:00
Stefan AgnerandGitHub 962f1bad32 Add mW as unit of measurement for Matter electrical power sensors (#133504) 2024-12-19 11:40:05 +00:00
Stefan AgnerandGitHub 9ab69aa41c Add mWh as unit of measurement for Matter energy sensors (#133005) 2024-12-13 09:33:58 +01:00
Josef ZweckandGitHub 3cfd958dc2 Allow mL/s as UnitOfVolumeFlowRate (#130771) 2024-11-21 20:47:24 +01:00
d8549409f7 Area units and conversion between metric and US (#123563)
* area conversions

* start work on tests

* add number device class

* update unit conversions to utilise distance constants

* add area unit

* update test unit system

* update device condition and trigger

* update statistic unit converters

* further tests work WIP

* update test unit system

* add missing string translations

* fix websocket tests

* add deprecated notice

* add more missing strings and missing initialisation of unit system

* adjust icon and remove strings from scrape and random

* Fix acre to meters conversion

Co-authored-by: epenet <[email protected]>

* Tidy up valid units

Co-authored-by: epenet <[email protected]>

* fix ordering of area

* update order alphabetically

* fix broken test

* update test_init

* Update homeassistant/const.py

Co-authored-by: epenet <[email protected]>

* remove deprecated unit and fix alphabetical order

* change deprecation and add tests, change to millimeter conversion for inches

* fix order

* re-order defs alphabetically

* add measurement as well

* update icons

* fix up Deprecation of area square meters

* Update core integrations to UnitOfArea

* update test recorder tests

* unit system tests in alphabetical

* update snapshot

* rebuild

* revert alphabetization of functions

* other revert of alphabetical order

---------

Co-authored-by: epenet <[email protected]>
2024-11-21 16:10:44 +01:00